Showing results: 16 - 30 of 136 items found.
-
40-204-001 -
Pickering Interfaces Ltd.
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
40-204-002 -
Pickering Interfaces Ltd.
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
Amprobe Test Tools
Amprobe’s Advanced Wire Tracers provide accurate results in minutes with new features and technologies that simplify wire tracing and breaker identification, including two optimal frequencies for both energized and de-energized wire and breaker tracing in walls, ceilings, and floors.
-
Extech CT20 -
Extech Instruments Corporation
The CT20 is an electronic tool for electricians, alarm, cable installers and others who routinely need to check circuits for continuity and also identify cables and wires. It allows a single user to quickly identify and label two wires even when the wire ends are located in different rooms. It can accommodate test wire lengths up to 10,000-feet (3,000 meters), 26-gauge minimum. The CT20’s Remote Continuity mode allows the user to check continuity and to identify two or more cables/wires simultaneously.
-
Langeo Co., Ltd.
The winch/reel is only for 1D vertical resistivity sounding(VES) survey, which will improve the working efficency in 1D geophysical investigation. There are two types: one for 200m copper wire, the other for 500m copper wire.
-
42-204-001 -
Pickering Interfaces Ltd.
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
42-204-002 -
Pickering Interfaces Ltd.
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
Extech Instruments Corporation
An electronic tool for electricians, alarm, cable installers and others who routinely need to check circuits for continuity and also identify cables and wires. It allows a single user to quickly identify and label two wires even when the wire ends are located in different rooms. It can accommodate test wire lengths up to 10,000-feet (3,000 meters), 26-gauge minimum.
-
40-201-004 -
Pickering Interfaces Ltd.
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
40-201-008 -
Pickering Interfaces Ltd.
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
DEVAR Inc.
Conversion of Thermocouple, RTD, millivolt and resistance signals from field sensors is accomplished using DEVAR two wire signal transmitters.
-
Static Solutions Inc.
Tests two people and two wriststrapsLED and buzzerNIST calibration includedWorks with all single wire capacitance wrist strapsAll cords suppliedCE markCan be calibratedProduct conforms to the ESD S.20.20 spec standards110v AC powerGround dock included
-
Supreme Instrument Laboratories
Three phase meter test bench suitable for calibration & testing of AC Ammeters, Voltmeters, Single phase Energy Meters, Watt Meters, Power Factor Meters, Three Phase Two Wire & Three Phase Four Wire Energy Meters Trivector Meters, Maximum demand indicators, of active & reactive systems, Three phase 3 wire & 4 wire watt meters, Var Meters, Power Factor Meters etc.
-
Extech TG20 -
Extech Instruments Corporation
The TG20 Wire Tracer Kit identifies wire pairs, check continuity and test telephone line polarity. Transmitter has output cables terminated in modular RJ11 phone connector. The non-contact amplifier probe audibly identifies the selected wire or cable so that you can easily trace from source to termination. Comes complete with Wire Tracer Probe and Transmitter with RJ11 phone connector, a pair of alligator clips and two 9V batteries.
-
40-200-008 -
Pickering Interfaces Ltd.
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.